aboutsummaryrefslogtreecommitdiff
path: root/plat/renesas/rcar/include/plat_macros.S
blob: 927cd39e8ff67c3e5394e37d76042721b2a46a7e (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
/*
 * Copyright (c) 2015-2017, Renesas Electronics Corporation. All rights reserved.
 *
 * SPDX-License-Identifier: BSD-3-Clause
 */

#include <drivers/arm/cci.h>
#include <drivers/arm/gic_common.h>
#include <drivers/arm/gicv2.h>

#include "rcar_def.h"

.section .rodata.gic_reg_name, "aS"
gicc_regs:
	.asciz "gicc_hppir", "gicc_ahppir", "gicc_ctlr", ""
gicd_pend_reg:
	.asciz "gicd_ispendr regs (Offsets 0x200 - 0x278)\n Offset:\t\t\tvalue\n"
newline:
	.asciz "\n"
spacer:
	.asciz ":\t\t0x"

	/* ---------------------------------------------
	 * The below macro prints out relevant GIC
	 * registers whenever an unhandled exception is
	 * taken in BL3-1.
	 * Clobbers: x0 - x10, x16, x17, sp
	 * ---------------------------------------------
	 */
	.macro plat_print_gic_regs
	mov_imm	x17, RCAR_GICC_BASE
	mov_imm	x16, RCAR_GICD_BASE
print_gicc_regs:
	/* gicc base address is now in x17 */
	adr	x6, gicc_regs	/* Load the gicc reg list to x6 */
	/* Load the gicc regs to gp regs used by str_in_crash_buf_print */
	ldr	w8, [x17, #GICC_HPPIR]
	ldr	w9, [x17, #GICC_AHPPIR]
	ldr	w10, [x17, #GICC_CTLR]
	/* Store to the crash buf and print to console */
	bl	str_in_crash_buf_print

	/* Print the GICD_ISPENDR regs */
	add	x7, x16, #GICD_ISPENDR
	adr	x4, gicd_pend_reg
	bl	asm_print_str
gicd_ispendr_loop:
	sub	x4, x7, x16
	cmp	x4, #0x280
	b.eq	exit_print_gic_regs
	bl	asm_print_hex
	adr	x4, spacer
	bl	asm_print_str
	ldr	x4, [x7], #8
	bl	asm_print_hex
	adr	x4, newline
	bl	asm_print_str
	b	gicd_ispendr_loop
exit_print_gic_regs:
	.endm

.section .rodata.cci_reg_name, "aS"
cci_iface_regs:
	.asciz "cci_snoop_ctrl_cluster0", "cci_snoop_ctrl_cluster1" , ""

	/* ------------------------------------------------
	 * The below macro prints out relevant interconnect
	 * registers whenever an unhandled exception is
	 * taken in BL3-1.
	 * Clobbers: x0 - x9, sp
	 * ------------------------------------------------
	 */
	.macro plat_print_interconnect_regs
	adr	x6, cci_iface_regs
	/* Store in x7 the base address of the first interface */
	mov_imm	x7, (CCI500_BASE + SLAVE_IFACE3_OFFSET)
	ldr	w8, [x7, #SNOOP_CTRL_REG]
	/* Store in x7 the base address of the second interface */
	mov_imm	x7, (CCI500_BASE + SLAVE_IFACE4_OFFSET)
	ldr	w9, [x7, #SNOOP_CTRL_REG]
	/* Store to the crash buf and print to console */
	bl	str_in_crash_buf_print
	.endm

	.macro plat_crash_print_regs
	plat_print_gic_regs
	plat_print_interconnect_regs
	.endm